Alternating Current · Lesson 2 of 9
Phase and Phasor Reasoning
“Translate sinusoidal timing into phasor angles and add voltages with their phases intact.”
• Interpret a rotating phasor as a representation of a scalar sinusoid. • Convert phase differences into time differences. • Distinguish lead and lag using a stated sine convention. • Add same-frequency voltages through perpendicular components.
Timing is part of an AC quantity
Two signals can have the same frequency and different peak times. Compare v = Vm sin(ωt) and i = Im sin(ωt − φ). In this chapter φ is the angle by which voltage leads current. Positive φ means current lags; negative φ means current leads. This convention will be kept throughout, including in capacitive circuits. A phase angle without its defining equations is ambiguous.
Differentiating sin(ωt) gives ω cos(ωt), whose positive maximum is a quarter-cycle earlier than the sine maximum. Integrating the sine gives −cos(ωt)/ω, whose positive maximum is a quarter-cycle later. These simple transformations explain the quarter-cycle relationships of capacitors and inductors; they are not arbitrary memorised rules.
A rotating arrow that represents a scalar
Imagine an arrow of fixed length Vm in a mathematical plane, rotating counterclockwise at angular speed ω. If its angle from the horizontal is ωt, its vertical projection is Vm sin(ωt). A second arrow at angle ωt − φ projects to the current. The angular separation remains fixed while both rotate. Their vertical projections can be positive or negative even though the arrow lengths are positive.
Voltage and current remain signed scalars; the arrow is a mathematical device, not a spatial voltage vector. Also, arrows measured in volts and amperes cannot be added as physical quantities. Their angles may be compared, with separately stated scales. In this chapter phasor lengths for derivations represent peak amplitudes. An entire diagram can instead use RMS lengths if all voltages use that convention consistently; the angles remain identical.
Freeze the diagram to compare phases
Since every phasor rotates together, we can freeze a snapshot and choose the current arrow horizontal. A resistive voltage lies along it, an inductive voltage 90° counterclockwise ahead, and a capacitive voltage 90° clockwise behind. This does not say that current is at its positive maximum at the displayed instant: vertical projection in the chosen sine picture would then be zero. The frozen view chiefly shows relative phase.
Why AC magnitudes do not simply add
Kirchhoff’s loop rule adds instantaneous voltages algebraically at each instant. Since a projection of a sum equals the sum of projections, adding same-frequency voltage phasors reproduces that rule at all times. For two perpendicular voltage phasors, the resultant amplitude follows Pythagoras. Their scalar magnitudes are not simultaneous maxima, so adding those magnitudes would overestimate the source peak.
For opposite phasors, subtract their signed components before taking a magnitude. For general angles use components along perpendicular axes. Phasor addition assumes a common angular frequency: arrows at different speeds do not form one fixed triangle. Non-sinusoidal signals may require several frequency components and lie beyond the single-phasor calculation.
Problem
At 50 Hz a sinusoidal current reaches its positive peak 2.5 ms after the voltage. Find the lag and write i(t) if Im = 4 A.
- 1.T = 20 ms. The delay is 1/8 cycle, so φ = 2π/8 = π/4 = 45°.
- 2.With v = Vm sin(100πt), i = 4 sin(100πt − π/4) A.
- 3.The positive sign of φ refers to a lag only because the defining current equation uses minus φ.
Problem
A resistor voltage is 120 V RMS and a perpendicular reactive voltage is 160 V RMS. Find source RMS voltage and phase magnitude.
- 1.Both voltages have the same frequency. V = √(120² + 160²) = 200 V, not 280 V.
- 2.|φ| = arctan(160/120) = 53.1°. For an inductive reactive voltage φ is positive; for a capacitive one it is negative.
- 3.Instantaneous voltages still sum exactly. A smaller resultant than the sum of magnitudes is a consequence of their different peak times.
Quick Quiz
Quiz
A phasor arrow represents
Explanation: Its projection represents a signed scalar quantity.
With i = Im sin(ωt − π/3), current
Explanation: Relative to v = Vm sin(ωt), minus π/3 delays corresponding features.
Perpendicular RMS voltages 3 V and 4 V have resultant
Explanation: The magnitude is √(3² + 4²) = 5 V.
Changing every voltage phasor from peak to RMS changes phase angles by
Explanation: All lengths scale equally by 1/√2, preserving angles.
A fixed phasor triangle directly describes signals with
Explanation: A fixed relative angle requires equal rotation rates.
Practice Problems
- A 100 Hz current lags its voltage by 30°. Find the peak delay.
- Two same-frequency voltages have opposite phasors of RMS lengths 90 V and 50 V. Find their resultant and explain the subtraction.
- A 60 V resistive voltage and 80 V capacitive voltage occur in series. Find source voltage and φ.
- Why does a 90° voltage-current phase difference not imply perpendicular electron motion?
- Write a 5 A peak current leading v = Vm sin(400t) by π/2 and give its value at t = 0.
T = 0.010 s. Delay = (30/360)T = 0.000833 s = 0.833 ms. Equivalently φ/ω = (π/6)/(200π).
Key Takeaways
• Phase specifies relative timing at a shared frequency. • We use i = Im sin(ωt − φ): positive φ is a lag. • A phasor projection represents a scalar sinusoid. • Peak and RMS phasors have the same phase angles. • Only compatible voltage phasors may be added as voltages. • Instantaneous voltages add algebraically; their amplitudes require phase-aware addition. • A fixed phasor construction describes sinusoidal steady state.
Finished this lesson? Mark it complete to track your progress.
Loading your progress…