Learning Objectives

• Select appropriate peak, RMS and instantaneous relationships. • Connect element laws to phase, impedance and resonance. • Solve mixed AC circuit and power problems with stated assumptions. • Analyse ideal transformer transfer and identify real losses.

One chain from waveform to useful energy

Begin an AC problem with the source waveform and its frequency. The source fixes how rapidly terminal voltage changes. Each element responds through its own physical law: R relates voltage to current, L relates voltage to the rate of current change, and C relates current to the rate of voltage change. These laws produce in-phase, lagging and leading responses. In a series circuit they apply to one common current; phasors combine the resulting voltages into the source waveform.

The circuit’s impedance determines current amplitude, while its signed net reactance determines lead or lag. The timing then determines average power. Resistance converts electrical energy irreversibly to heat; inductance and capacitance store and return it in the ideal model. A transformer uses changing magnetic flux to transfer energy between circuits at different voltage and current levels. These are connected applications of charge conservation, induction and energy conservation.

Waveforms and effective values

Timing and sine-wave RMSLaTeX
f is in Hz, ω in rad s⁻¹, T in s, V in V and I in A. The RMS conversion applies to a pure sinusoid; the RMS integral definition applies more generally.

The RMS derivation squares the sine waveform, uses sin²θ = (1 − cos 2θ)/2, averages the cosine to zero, and takes the square root. Consequently zero signed mean current does not imply zero mean heating. An instantaneous value can be smaller than, equal to, or larger than the RMS value during different parts of a cycle. Do not substitute an RMS voltage into an instantaneous sine equation as though it were its peak.

Element laws, phase and stored energy

ElementPassive time-domain lawSine-wave response and energy
ResistorvR = RiIn phase; mean power I²R in W
Ideal inductorvL = L di/dtCurrent lags by 90°; UL = ½Li² in J
Ideal capacitori = C dvC/dtCurrent leads by 90°; UC = ½CvC² in J

Integrating the inductor voltage produces a negative cosine plus a constant set by initial current. The pure sine response selects the zero-offset solution. Differentiating capacitor charge produces a positive cosine. These are the mathematical reasons for lag and lead. Real winding resistance, dielectric loss and core loss modify the ideal zero-dissipation predictions. A fixed phasor diagram describes sinusoidal steady state, not an arbitrary switch-on transient.

A formula reference with conditions

RelationshipMeaning and unitsUse conditions
XL = ωL; XC = 1/(ωC)Reactance magnitudes in Ω; L in H, C in FIdeal linear elements at angular frequency ω
Z = √[R² + (XL − XC)²]; I = V/ZSeries opposition in Ω and RMS current in AOne series path, sinusoidal steady state
tanφ = (XL − XC)/RLag angle φ for i = Im sin(ωt − φ)R > 0; retain sign of net reactance
VR = IR; VL = IXL; VC = IXCRMS component voltage magnitudes in VUse the common series RMS current
ω0 = 1/√(LC); f0 = ω0/(2π)Resonant angular and ordinary frequenciesIdeal series elements with fixed positive R
Q = ω0L/R = 1/(ω0CR)Dimensionless selectivity and voltage magnificationSeries resonance with fixed ideal parameters
P = VI cosφ = I²RMean real power in WSinusoidal steady state; R is total dissipation
Vs/Vp = Ns/Np; Is/Ip = Np/NsIdeal transformer voltage and load-current ratiosShared flux, negligible losses and magnetising current
η = Pout/Pin; Pline = I²rEfficiency and resistive line heatingUse real powers and distinguish line r from load R

Reconstructing impedance rather than memorising it

Take current horizontal. The resistor voltage is IR along it, while the net vertical voltage is I(XL − XC). Pythagoras gives V² = I²R² + I²(XL − XC)². Factor out I² and take the positive square root to obtain V = IZ. Dividing the vertical component by the horizontal gives tanφ. The same geometry works with all-peak values; mixing peak and RMS lengths does not.

VR = IRVL − VCV = IZφInductive case shown: VL > VC, so voltage leads current.
Series voltage phasor construction— Schematic; labels describe the physical quantities.

When frequency rises, XL rises but XC falls. Below resonance the capacitive response dominates; above it the inductive response dominates. At resonance the two cancel, Z = R and source current is in phase with source voltage. This cancellation is of voltages, not of energy storage or of the common current. Large equal and opposite component voltages can demand high component voltage ratings.

Resonance, free oscillations and power connect

The source-free ideal LC equation is q″ + q/(LC) = 0. Its charge and current exchange electric and magnetic energy at angular frequency 1/√(LC). Adding resistance causes decay; a sustained drive replaces energy lost to heat. In the driven series model current resonance occurs where XL = XC. That condition gives the same undamped LC frequency, while R determines the finite current and sharpness.

To derive mean power, multiply the sine voltage and phase-shifted sine current. The product has a constant term (VmIm/2)cosφ and an oscillating cosine term whose cycle mean vanishes. Thus P = VI cosφ. The ideal series voltage triangle gives cosφ = R/Z, so P = I²R. Reactive elements can return energy at individual instants even while the whole passive load absorbs positive mean power.

Combine impedance, phase and power

Problem
R = 6 Ω, XL = 10 Ω, XC = 2 Ω and V = 100 V RMS at one source frequency. Find current, phase, power and voltage drops.

  1. 1.Net reactance is +8 Ω. Z = √(6² + 8²) = 10 Ω and I = 10 A. φ = arctan(8/6) = 53.1°, a lag.
  2. 2.VR = 60 V, VL = 100 V and VC = 20 V. Their resultant is √(60² + 80²) = 100 V.
  3. 3.cosφ = 0.60, so P = 100 × 10 × 0.60 = 600 W. I²R = 10² × 6 gives the same result; S = 1000 VA.
Move the same load to resonance

Problem
A series R = 3 Ω, L = 25.48 mH, C = 796 μF circuit uses a source of fixed peak 283 V. Estimate resonance frequency, RMS current and power.

  1. 1.LC ≈ 2.028 × 10⁻⁵ s², giving ω0 ≈ 222.0 rad s⁻¹ and f0 ≈ 35.34 Hz.
  2. 2.At resonance, V = 283/√2 ≈ 200.1 V, Z = 3 Ω and I = 66.70 A.
  3. 3.P = V²/R ≈ 13.35 kW. Raising current at resonance also raises real resistor heating; ideal L and C do not supply this power.

Transfer power without creating it

In a transformer, divide the two Faraday-law emf magnitudes to cancel the common flux derivative, obtaining the turns ratio. Match real input and output power for the lossless case to obtain the reciprocal load-current ratio, with power factors included when relevant. The secondary load fixes its current; the primary then responds to that load. Real efficiency accounts for winding and core losses. A voltage step-up alone is not an energy gain.

For fixed delivered real power and power factor, high transmission voltage reduces current and therefore I²r line loss. Parallel capacitive correction reduces the upstream reactive current of an inductive load while maintaining its terminal voltage. These two techniques reduce line current for different reasons: voltage conversion changes voltage level, while correction changes the line-current phase composition.

Checking a solution before trusting it

State the waveform, reference phase, RMS or peak convention and idealisations. Convert mH and μF to H and F. Check ω against 2πf. Preserve the sign of XL − XC separately from Z. Verify component voltages with their phase triangle, mean power by both VI cosφ and I²R where applicable, and transformer results by real-power balance. Check that no ideal lossless element has been assigned irreversible heating and that an approximate model is not used outside its stated limits.

Quick Quiz

Quiz

Quick check

A 100 V RMS sine source has peak

Explanation: The peak is √2 times RMS.

Quick check

In a series circuit with XC > XL, current

Explanation: The signed lag angle is negative.

Quick check

At resonance, the source RMS voltage equals

Explanation: The opposite reactive phasors cancel.

Quick check

An ideal transformer step-up produces extra output energy by

Explanation: Ideal output power equals input power; current changes reciprocally.

Quick check

A 200 V RMS, 2 A load at power factor 0.5 absorbs

Explanation: P = VI cosφ = 200 × 2 × 0.5 = 200 W.

Practice Problems

Practice Problems
  1. A 150 Ω resistor uses 120 V RMS, 60 Hz. Find RMS current, peak current, mean power and energy per cycle.
  2. A sine voltage is 200 sin(100πt) V. Find RMS voltage, frequency and the first positive peak time.
  3. An ideal 50 mH inductor uses 100 V RMS at 50 Hz. Find current, phase and mean power.
  4. An ideal 20 μF capacitor uses 100 V RMS at 50 Hz. Find current and its change if frequency triples.
  5. A series circuit has R = 8 Ω, XL = 4 Ω, XC = 10 Ω and V = 100 V RMS. Find Z, current, phase, power and component voltages.
  6. For L = 0.20 H, C = 50 μF, R = 10 Ω and V = 20 V RMS, find resonance frequency, current and Q.
  7. An ideal free LC loop has C = 8 μF, L = 0.50 H and initial voltage 50 V. Find total energy, angular frequency and peak current.
  8. A 230 V RMS load takes 10 A at lagging power factor 0.6. Find real power and ideal line current after unity-factor parallel correction.
  9. An ideal 240 V to 12 V transformer supplies a 6 Ω resistor. Find output current, primary current and power.
  10. A fixed 50 kW unity-factor load is supplied at 5 kV through a 4 Ω line. Find line loss, then repeat at 10 kV and explain the change.

I = 120/150 = 0.800 A; Im = √2I = 1.13 A. P = V²/R = 96.0 W. T = 1/60 s, so energy per cycle is 96/60 = 1.60 J. Both voltage and current reverse, but resistor power stays nonnegative.

Key Takeaways

Key Takeaways

• Start with the waveform and keep RMS, peak and instantaneous values distinct. • Element laws explain phase: R is in phase, L gives lag and C gives lead. • Series impedance combines resistance with signed net reactance. • At resonance reactive voltages cancel while energy storage continues. • Mean sinusoidal real power is VI cosφ and equals I²R in the ideal series model. • An ideal transformer changes voltage and load current while conserving power. • Real losses, initial conditions and model limits must remain explicit. • Use units, phase geometry and independent energy checks to verify answers.