Wave Optics · Lesson 7 of 8
Polarisation and Optical Filters
“Use transverse field projection to explain polarisers, Malus’ law and the surprising transmission through three filters.”
• Explain linear polarisation and unpolarised light using transverse electric fields. • Distinguish transmission axes from absorbing molecular directions. • Derive Malus’ law and the ideal one-half rule for unpolarised input. • Calculate successive-filter intensities with clearly defined incident values.
Polarisation identifies a transverse oscillation direction
Imagine a wave travelling along a stretched string in the x direction. If its displacement is always along y, it is a linearly polarised transverse wave. A z-directed displacement is another linear polarisation. The wave travels along x even though the string points move sideways; propagation direction and vibration direction must be kept distinct. Light is not a material string, but its transverse electric-field direction plays the corresponding role.
For an ideal plane light wave travelling along +x, E lies in the yz plane. Linear polarisation means its oscillating E remains along one fixed line in that transverse plane, reversing sign during each cycle. A y-polarised and a z-polarised beam can have the same frequency and travel direction while interacting differently with an optical filter. Their magnetic fields remain perpendicular to both E and propagation.
A longitudinal sound wave in air has oscillatory displacement along its travel direction, leaving no analogous freely selectable transverse displacement axis. Interference and diffraction can occur for sound, but this optical axis-selection behaviour reveals the transverse character of light. Polarisation therefore supplies information that a simple observation of interference alone does not establish.
Unpolarised is not the same as no electric field
Ordinary thermal light, such as light from a typical lamp, has rapidly fluctuating transverse electric-field orientation with no persistent preferred axis over the measurement. This is described as unpolarised. Its instantaneous field is not zero, and it still transports energy. The description is statistical: over many contributions and times the transverse orientations are symmetrically represented.
Linear polarisation is not the only possible organised polarisation state, but other states need not be developed here. Avoid calling every field whose direction changes unpolarised: a deterministic rotating field can have an organised state. For present calculations, unpolarised input means the orientation average is uniform in the transverse plane, while linearly polarised input has a known fixed axis.
A transmission axis passes a component
An ideal linear polariser transmits the E component along its transmission, or pass, axis and rejects the perpendicular component. In a common absorbing-sheet model, aligned conducting molecular structures absorb preferentially for E parallel to them, so the transmission axis is perpendicular to that absorbing alignment. Real polariser technologies differ; the reliable calculation reference is the stated transmission axis rather than an assumed drawing of molecular chains.
Projection gives the cosine for the field. Squaring gives cosine-squared for intensity because both beams are compared in the same surrounding medium. The intensity is never negative: an angle beyond 90° can reverse the signed field component without making negative power. Parallel axes give full ideal transmission of the already polarised input; crossed axes give zero. Real filters have additional losses and imperfect extinction.
The intensity repeats after 180°, because an axis is a line rather than a directed arrow. Starting at a maximum, minima occur at 90° and 270°, with the other maximum at 180°. Counting 360° as a new independent orientation would double count the starting direction. A single ideal polariser rotated in unpolarised light transmits the same mean fraction at every angle, because the incident field has no preferred transverse axis.
Why the first polariser transmits half of unpolarised input
Resolve each instantaneous transverse orientation along the selected axis. The mean of cos²θ over uniformly sampled orientations is one half: sine-squared and cosine-squared have equal orientation averages, and their sum is one. Thus an ideal polariser transmits half the incident unpolarised intensity and leaves a linearly polarised beam along its own axis. This one-half step occurs before applying Malus’ law to a later analyser.
Problem
An unpolarised beam of intensity 80 W/m² passes an ideal polariser and then an analyser at 60° to it. Find both outputs.
- 1.The first output is I₁ = 80/2 = 40 W/m². It is now linearly polarised.
- 2.The second output is I₂ = 40 cos²60° = 40/4 = 10 W/m². Using 80 cos²60° would skip the first loss; applying an extra one-half after Malus would double count a loss.
Three filters can transmit where two crossed filters do not
Label the filters in beam order P₁, P₂ and P₃. Let the first and last axes be crossed: P₁ at 0° and P₃ at 90°. Insert P₂ between them at angle θ to P₁. The field leaving P₂ is aligned with P₂, so it has a nonzero projection along P₃ unless P₂ is parallel to either end filter. The middle filter changes the polarisation direction of the transmitted portion; it does not amplify energy.
Problem
The original unpolarised intensity is 120 W/m². Outer filters are crossed and the middle filter is at 45°. Find the final intensity.
- 1.After P₁: I₁ = 60 W/m². After P₂: I₂ = 60 cos²45° = 30 W/m².
- 2.The last angle is also 45°, so I₃ = 30/2 = 15 W/m² = 120/8. Without P₂, ideal crossed P₁ and P₃ would transmit zero.
- 3.Adding a filter can raise the final transmitted value relative to that zero-output arrangement while every individual filter still only removes power from its own input.
Uses and a simple observation
Polarising filters can regulate intensity and reduce a suitably polarised component of reflected glare. Sunglasses and camera filters exploit such selectivity; an unpolarised component is still reduced by the ordinary first-filter loss. Some stereoscopic displays send differently polarised image channels to the two eyes through corresponding filters, although not every 3D system uses the same polarisation method. These applications depend on field orientation, not a change in vacuum speed.
For a controlled observation, use two filter sheets and a diffuse lamp. Rotate one sheet relative to the other and compare parallel and crossed settings. Then keep the outer pair crossed and insert a third sheet at intermediate angles. Measure transmitted light with a suitable sensor or observe moderate lamp brightness; do not view the Sun or a laser through the sheets. A filter that appears dark to the eye is not automatically certified protection for every radiation source.
Quick Quiz
Quiz
Linear polarisation of light specifies
Explanation: The electric field oscillates along a fixed line perpendicular to travel.
An ideal polariser receiving unpolarised intensity I_u transmits
Explanation: The orientation average of cos²θ is one half.
Malus’ law at analyser angle 60° transmits what fraction of an already linearly polarised input?
Explanation: cos²60° = 1/4; no initial unpolarised half-factor applies to this stated input.
Crossed outer filters with an intermediate 45° filter transmit what fraction of the intensity after the first filter?
Explanation: Two successive 45° projections each transmit one half, giving one quarter of I₁.
Why does inserting that middle filter not violate energy conservation?
Explanation: The comparison changes the arrangement; each filter still removes or rejects energy.
Practice Problems
- A linearly polarised input of 100 W/m² reaches an ideal analyser at 30°. Find output and explain why there is no factor of one half first.
- An unpolarised 200 W/m² beam passes two ideal filters at 45°. Find the output after each.
- Derive the three-filter maximum when the outer axes are crossed and the middle angle is variable.
- At what analyser angles from 0° to less than 360° is the output one quarter of a linearly polarised input?
- Explain why interference and diffraction alone do not establish that a wave is transverse, whereas optical polarisation provides that evidence.
Malus gives I = 100 cos²30° = 75 W/m². The beam is already linearly polarised, so only its projection onto this analyser axis is needed. The one-half rule applies to a separate first filtering of unpolarised input, which is not part of the stated problem.
Key Takeaways
• Polarisation describes transverse electric-field orientation. • Unpolarised light has no preferred transverse orientation over the measurement. • The pass axis specifies the electric component an ideal polariser transmits. • Malus’ law is I_out = I_in cos²θ for linearly polarised input. • An ideal first polariser transmits half of unpolarised intensity. • Successive filters require applying projection factors in beam order. • A middle 45° filter between crossed outer filters gives I₁/4, or I_u/8 for original unpolarised input. • Polarisation behaviour is distinct evidence of transverse wave structure.
Finished this lesson? Mark it complete to track your progress.
Loading your progress…