Magnetism and Matter · Lesson 5 of 8
Magnetisation, Magnetic Intensity and Permeability
“Separate the magnetic moment density of matter from H and B, and calculate the response of a material-filled long solenoid.”
• Calculate magnetisation as net moment per volume. • Distinguish B, H and M using definitions and units. • Derive the relationships between susceptibility and permeability. • Apply the long-solenoid model without assuming a universal linear material response.
From many atomic moments to one bulk response
A piece of matter contains a very large number of microscopic magnetic moments. Their vector sum may be nearly zero even when each atom or ion has a moment. A field can change the balance of orientations or induce additional moments. To compare two differently sized specimens, divide the net moment by sample volume. Magnetisation measures how strongly each unit volume is magnetised, rather than how much material is present.
Doubling the volume at unchanged uniform M doubles the total moment. It does not double the magnetisation. Oppositely oriented microscopic moments cancel in the vector sum; adding the magnitudes would wrongly predict that an unmagnetised specimen must have a large bulk moment. The same distinction will explain why a ferromagnet can contain magnetised domains yet have almost no overall moment.
Problem
A uniformly magnetised 5.0 cm³ specimen has net moment 0.020 A m². Find M, and the moment of an otherwise identical 2.0 cm³ piece.
- 1.Convert 5.0 cm³ to 5.0 × 10⁻⁶ m³. Thus M = 0.020/(5.0 × 10⁻⁶) = 4000 A/m.
- 2.At the same M, a 2.0 × 10⁻⁶ m³ piece has m = MV = 0.0080 A m².
- 3.This assumes cutting has not changed magnetisation. The intensive quantity M stays fixed; the extensive moment changes with volume.
Why H is useful
First consider an ideal long empty solenoid with n turns per metre and current I. Well inside and far from the ends its field is B₀ = μ₀nI. Fill its interior with a uniform magnetic material while holding the free winding current fixed. The material can contribute additional field. In this long axial geometry, with end effects neglected, the contribution is μ₀M and the total B is μ₀(nI + M). A diamagnet has M opposed to the applied direction, so the total can be smaller, not larger, than B₀.
For the long uniformly filled solenoid with negligible end effects, H = nI along the axis. It is set by the winding’s free current in this geometry. Changing the material at fixed nI changes M and B. For a short specimen, its shape can produce a demagnetising field and change the internal H. Therefore H = B₀/μ₀ with B₀ interpreted as the empty-solenoid field is a useful result for this specified setup, not a universal rule for every magnetic body.
Susceptibility connects the material response to H
For a linear, isotropic material in an appropriate field and temperature range, M is proportional to H and parallel or antiparallel to it. Write M = χH in vector form, with scalar susceptibility χ. Positive χ gives a response along H, negative χ one against H. Since both vectors have units A/m, χ is dimensionless. Anisotropic materials require more general directional relations; ferromagnets can be nonlinear and history dependent.
Substitute χH for M in B = μ₀(H + M). Factor H to obtain B = μ₀(1 + χ)H. Define relative permeability μr = 1 + χ and permeability μ = μ₀μr. Thus B = μH in this model. Relative permeability is dimensionless; permeability itself has units T m/A or N/A². Giving one of χ, μr or μ determines the other two only within the same stated model and conditions.
| Quantity | Meaning | SI units | Common confusion |
|---|---|---|---|
| m | Net magnetic dipole moment | A m² = J/T | Not mass, despite the letter |
| M | Net magnetic moment per volume | A/m | Not the same as total moment |
| H | Magnetic intensity, B/μ₀ − M | A/m | Not measured in tesla |
| B | Magnetic flux density | T | Not equal numerically to H |
| χ; μr | Susceptibility; relative permeability | Dimensionless | μr = 1 + χ, not χ |
| μ; μ₀ | Material; vacuum permeability | T m/A | Neither is dimensionless |
Problem
A long solenoid has n = 1000 m⁻¹, I = 2.0 A, and a core with effective μr = 400 at this operating point. Find H, M and B.
- 1.H = nI = 2000 A/m. The implied χ = μr − 1 = 399.
- 2.M = χH = 399 × 2000 = 798000 A/m.
- 3.B = μ₀μrH = 4π × 10⁻⁷ × 400 × 2000 = 1.00531 T, approximately 1.0 T at the input precision.
- 4.Check the definition: μ₀(H + M) = μ₀ × 800000 A/m, the same result. Treat μr = 400 as an effective specified value here; it need not stay constant as current changes.
Replacing the material contribution by an equivalent winding current
The magnetisation in a long core can be represented by an equivalent surface-current contribution to its field. To reproduce the same B after removing the core, the empty solenoid must carry total current Ieq satisfying μ₀nIeq = B. The original current I is already present; the additional equivalent current is IM = Ieq − I. It is not an actual extra conduction current flowing through the insulated core.
For the preceding data, Ieq = 400 × 2.0 = 800 A and IM = 798 A. Keep the unrounded B = 1.00531 T until the final step. Substituting a rounded field of 1 T prematurely would give a different approximate current and obscure the exact consistency of the specified model. Equivalent current is a mathematical comparison; designing such a winding would also require thermal and electrical engineering.
Quick Quiz
Quiz
Magnetisation is
The vector moment density is M = mnet/V.
Which two quantities have SI units A/m?
Both M and H have units A/m, whereas B is measured in tesla.
A linear material has χ = 0.002. Its relative permeability is
Relative permeability includes the vacuum baseline: μr = 1 + χ = 1 + 0.002 = 1.002, so the field is slightly enhanced.
At fixed free current in the ideal long filled solenoid, replacing its core changes
The fixed free-current geometry fixes H; material response controls M and hence B.
A constant scalar χ is generally insufficient for
Nonlinearity and memory mean a single constant proportionality cannot describe the full cycle.
Practice Problems
- A 4.0 cm³ specimen has moment 0.012 A m². Find M and its moment if the volume doubles at fixed M.
- A long solenoid has n = 1500 m⁻¹, I = 0.20 A and χ = 0.010. Find H, M, μr and B.
- For μr = 400, n = 1000 m⁻¹ and I = 2.0 A, calculate the empty-solenoid total and extra currents giving the same field.
- Derive μr = 1 + χ and give its assumptions.
- Why does H = nI need a geometry condition while B = μ₀(H + M) is a definition?
V = 4.0 × 10⁻⁶ m³, so M = 3000 A/m. Twice the volume at unchanged M gives twice the net moment, 0.024 A m². Magnetisation is unchanged because it is moment density.
Key Takeaways
• Magnetisation is vector magnetic moment per volume, in A/m. • H and M have the same units; B is measured in tesla. • B = μ₀(H + M) defines magnetic intensity. • H = nI applies to the specified long-solenoid geometry with negligible end effects. • For linear isotropic response M = χH and μr = 1 + χ. • A negative susceptibility reduces B in the long-solenoid model. • An equivalent magnetising current represents material field contributions, not a literal core conduction current. • Ferromagnetic response may require field-dependent and history-dependent descriptions.
Finished this lesson? Mark it complete to track your progress.
Loading your progress…