Magnetism and Matter · Lesson 7 of 8
Ferromagnetism and Permanent Magnets
“Use domains and their response to explain strong magnetisation, persistent magnets, soft cores and temperature effects.”
• Explain how magnetic domains produce strong collective response. • Distinguish an unmagnetised specimen from unmagnetised microscopic regions. • Choose hard and soft magnetic materials for appropriate uses. • Explain saturation, magnetic history and the loss of spontaneous ordering on heating.
Why iron responds much more strongly than aluminium
Bring a magnet near iron and near an equal-sized piece of aluminium under comparable conditions. Iron can respond dramatically more strongly. The difference is not just that iron has more individual moments. In a ferromagnetic material, interactions between neighbouring microscopic moments favour collective alignment. The cooperative mechanism requires quantum physics. It is not adequately explained by classical dipoles independently turning in the applied field.
A magnetic domain is a region in which a large collection of atomic moments is ordered in a common direction. A domain can therefore be strongly magnetised before an external field is applied. Different domains in an unmagnetised specimen can point in different directions, giving nearly zero vector sum for the whole specimen. “Unmagnetised iron” need not mean that every atom or domain has zero moment.
How a specimen acquires a large net moment
An applied field favours domains whose magnetisation has a component along it. Domain walls can move so those domains grow at the expense of less favourably oriented ones. Magnetisation within domains can also rotate towards the field. Both mechanisms increase the bulk moment. This collective response can be much larger than the weak statistical alignment of independent paramagnetic moments.
At high enough field most of the available moment is aligned and magnetisation approaches saturation. M cannot grow without bound with H. B can still increase through its μ₀H contribution even when M is nearly saturated. A straight-line law with one large constant susceptibility therefore cannot describe the entire process. When a large effective permeability is supplied for a calculation, treat it as a specified operating-point approximation.
Problem
Four equal-volume domains each have moment magnitude 0.010 A m². Initially two point +x and two point −x. A field changes the arrangement to three +x and one −x. Find initial and final net moments.
- 1.Initially mnet = (2 − 2) × 0.010 = 0, although every domain has a nonzero moment.
- 2.Finally mnet = (3 − 1) × 0.010 = 0.020 A m² towards +x.
- 3.If all four become +x, the maximum in this simplified model is 0.040 A m². Real magnetisation can involve wall movement and rotation rather than equal rigid domains flipping as units.
Magnetic history and retained magnetisation
After the external field is removed, domain walls and orientations need not immediately return to their original arrangement. Material structure can hinder that return. A specimen may retain a remanent magnetisation: the final state depends partly on the field history. This memory is why a description using M = χH with one constant χ can fail for a ferromagnet. It is also why preparing a specimen matters when comparing measurements.
Hard magnetic materials resist demagnetisation and retain useful magnetisation. They are suited to permanent magnets in compass needles and other devices needing a field without continuous winding current. Hard magnetic behaviour concerns magnetic persistence, not necessarily mechanical hardness. Alnico alloys containing aluminium, nickel and cobalt with iron and other constituents are one example.
Soft magnetic materials are readily magnetised and demagnetised, making them useful as temporary cores for electromagnets. Soft iron can greatly increase the field for a given winding current in a suitable geometry, then lose much of its induced bulk magnetisation when the current is removed. It is misleading to promise exactly zero remanence in every soft specimen. Processing, shape and field history influence the remaining moment.
| Property or use | Hard magnetic material | Soft magnetic material |
|---|---|---|
| Desired response after field removal | Retain a substantial useful moment | Lose most induced bulk magnetisation readily |
| Change of magnetisation | Resists reversal/demagnetisation | Changes relatively easily |
| Typical use | Permanent magnet; compass needle | Temporary electromagnet core |
| Suitable example | Alnico permanent-magnet alloy | Soft iron |
| What cannot be inferred | Mechanical hardness from the name alone | Exactly zero residual magnetisation for every sample |
Temperature can destroy collective ordering
Iron, cobalt and nickel are familiar ferromagnetic elements under ordinary conditions. Some other elements, including gadolinium, show ferromagnetic order only below material-specific temperatures. Thermal fluctuations compete with collective order. Heating a ferromagnet sufficiently can destroy its spontaneous magnetisation, and above its Curie temperature it behaves as a paramagnet rather than retaining ferromagnetic ordering.
Heating is therefore capable of weakening or destroying a permanent magnet. Cooling again below the ordering temperature does not guarantee recovery of its original net moment: ordered domains can form with different orientations, so the vector sum may be small. A suitable magnetising field can be needed to prepare a desired permanent state again. An external field can still induce magnetisation above the transition; losing spontaneous ferromagnetic order does not mean every magnetic response vanishes.
A useful observational test applies a controlled field to a prepared sample and measures magnetisation while increasing the field, then decreasing it. Failure to retrace the same values reveals magnetic memory. Separately, comparing response at controlled temperatures reveals changes in ordering. These are qualitative experimental designs; neither invents numerical measurements nor assumes a universal transition curve for all materials.
Other magnetic orders and the limits of the model
The three-way classification into dia-, para- and ferromagnets is a useful introduction, not an exhaustive list of magnetic order. Antiferromagnets have compensating ordered moments, while ferrimagnets have opposing groups with unequal net contributions. Magnetite, the principal magnetic material in natural lodestone, is ferrimagnetic; it should not be presented as a strictly ferromagnetic microscopic example. Spin-glass behaviour and other more complex orders also exist, but need not be developed to use the present models.
Domain sizes depend strongly on composition, microstructure and geometry. A single typical size paired with one fixed atom count is not a reliable universal statement. For this chapter, the essential point is that a domain contains many ordered microscopic moments. The diagram is a model of their directions, not a picture of isolated giant atoms or literal closed electronic circuits.
Problem
Two candidate materials respond strongly to a magnetising field. A retains nearly all its magnetisation after removal; B loses most and reverses readily. Choose a material for a compass and for a repeatedly switched electromagnet.
- 1.Use A for the compass because the needle needs a persistent magnetic moment without continuous current.
- 2.Use B for the switched electromagnet because its core should respond strongly while current is present and release most magnetisation when it is removed.
- 3.The choice is about retention and ease of changing magnetic state, not simply whichever specimen once showed the largest B. Other design requirements can matter in real devices.
Quick Quiz
Quiz
An unmagnetised multidomain ferromagnet can have
Individual domains are ordered while differently oriented domains can cancel in bulk.
A field can increase ferromagnetic magnetisation by
Favourably oriented domains can grow, and magnetisation can rotate towards the field.
A repeatedly switched temporary electromagnet usually benefits from
A soft core magnetises strongly and can lose most induced magnetisation when the applied field is removed.
Above its Curie temperature a ferromagnet ordinarily becomes
Spontaneous collective order is lost, but a paramagnetic response to an applied field remains.
When M is saturated, increasing H further means
The defining relation includes both H and M. Saturation of M does not eliminate the H contribution to B.
Practice Problems
- Why can strongly magnetised domains give a small total moment?
- A sample has moment 0.10 A m² at H = 100 A/m. After H is removed it retains 0.07 A m². Why is a single constant χ model inadequate for the entire sequence?
- An ideal domain model has six equal moments of 0.020 A m². Four point +x and two −x. Find net moment and saturation moment.
- Explain why cooling a heated magnet below its ordering temperature may not recover the original compass behaviour.
- Select soft iron or Alnico for a temporary lifting core and a persistent compass needle, and explain a limitation.
Total moment is a vector sum. Large moments in different directions can nearly cancel. Applying a field can change domain volumes and orientations so cancellation becomes incomplete; the bulk moment then grows without creating magnetic monopoles.
Key Takeaways
• Ferromagnetic response is collective and requires a quantum explanation at microscopic level. • A domain is locally ordered even when the whole sample has nearly zero moment. • Field-driven wall movement and rotation increase bulk magnetisation. • Saturation limits M; it does not necessarily make B constant. • Magnetic history can leave remanent magnetisation and invalidate one constant χ. • Hard magnetic materials suit permanent magnets; soft materials suit temporary cores. • Heating above the Curie temperature destroys spontaneous ferromagnetic order. • The introductory three-way classification does not include every type of magnetic ordering.
Finished this lesson? Mark it complete to track your progress.
Loading your progress…