Electromagnetic Induction · Lesson 6 of 9
Mutual Induction and Coupled Coils
“Explain and calculate flux linkage and induced emf between neighbouring circuits.”
• Define mutual inductance with a clear source–receiver convention. • Derive mutual inductance of long coaxial solenoids. • Use reciprocity to choose a simpler field calculation. • Calculate induced emf and flux-linkage change separately.
A changing current can act across an insulating gap
Place two insulated coils near one another. A current in coil 2 produces a magnetic field, part of which passes through coil 1. If the current in coil 2 changes, the flux linkage of coil 1 changes and an emf appears in coil 1. Electrical contact between the coils is unnecessary. Energy is transferred through their electromagnetic interaction; the receiver is not receiving conduction electrons directly from the source coil.
To describe this coupling, hold both coils fixed and assume a linear magnetic medium. Doubling source current doubles its field and the resulting receiver flux linkage. Their ratio is a property of the geometry, orientations and medium. In this approximation it stays constant while the current changes. Moving a coil or saturating an iron core can change that ratio, so the simplest proportional model must then be reconsidered.
The henry is the SI unit of inductance: 1 H = 1 Wb/A = 1 V s/A. A mutual inductance magnitude of 1 H produces 1 V of induced emf when the source current changes at 1 A s⁻¹. A large steady current may create large linked flux but produces no mutual emf once it stops changing. A smaller rapidly changing current may produce a much larger emf.
Derive M for two long coaxial solenoids
Let two very long coaxial solenoids overlap over length l. The inner one has area A₁ and n₁ turns per metre; the outer one has area A₂ greater than A₁ and n₂ turns per metre. First pass source current I₂ through the outer solenoid. Neglect end effects: its field in the inner region is B₂ = μ₀n₂I₂. Each inner turn links B₂A₁, and the inner coil has N₁ = n₁l turns. Multiply to obtain its total linkage.
Now reverse the roles. Source current I₁ through the inner solenoid gives B₁ = μ₀n₁I₁ mainly within its own cross-section. Although an outer turn encloses area A₂, the ideal inner-solenoid field occupies only A₁. Thus flux through each outer turn is B₁A₁, not B₁A₂. Multiplying by n₂l gives the same coefficient. This shared-area argument is the central geometric step; using the larger coil’s full area overestimates coupling.
Problem
Air-core coaxial solenoids have n₁ = 1000 m⁻¹, n₂ = 1500 m⁻¹, A₁ = 2.0 × 10⁻⁴ m² and l = 0.50 m. Find M and emf when I₂ rises at 20 A s⁻¹.
- 1.M = (4π × 10⁻⁷)(1000)(1500)(2.0 × 10⁻⁴)(0.50) = 1.885 × 10⁻⁴ H.
- 2.The induced emf magnitude is M|dI₂/dt| = 3.77 × 10⁻³ V. With the positive linkage convention above, an increasing positive I₂ gives negative receiver emf.
- 3.A high turn density does not by itself guarantee a large voltage; shared area, overlap length and current-change rate all matter.
Use reciprocity to avoid a difficult field integral
Consider concentric single-turn circular loops with radii a and b, where a is much smaller than b. The large loop’s field is nearly uniform over the small loop and approximately equals its central field μ₀I/(2b). Calculating the reverse linkage directly is harder because the small loop’s field varies over the large loop’s surface. Reciprocity lets us calculate the easy direction and use the same M in reverse.
Problem
Two single-turn concentric loops have radii a = 0.010 m and b = 0.10 m. Estimate M.
- 1.M ≈ (4π × 10⁻⁷)π(0.010)²/(2 × 0.10) = 1.97 × 10⁻⁹ H.
- 2.The value is about 2.0 nH. It is small because a one-turn small receiver encloses little area. The ratio a/b = 0.10 supports an approximate central-field calculation; the formula would fail as a approaches b.
Linkage change is not emf
If current rises by ΔI₂, the receiver linkage changes by MΔI₂. The induced average emf additionally requires division by the time interval and a minus sign. A question asking change in flux linkage is answered in Wb-turn; a question asking emf is answered in V. Likewise the per-turn flux change is linkage change divided by N₁ when equal linkage per turn is justified.
If both circuits carry changing currents, the linkage of coil 1 includes its own contribution and the other coil’s: λ₁ = L₁I₁ + M₁₂I₂ in a fixed linear model. Its induced emf is the negative derivative of that sum. Winding references determine the sign of M in a circuit equation. Coupling strength and induced-current direction are related but separate issues: use geometry and Lenz’s law rather than assuming every secondary current flows opposite to a primary current arrow.
Quick Quiz
Quiz
A mutual inductance of 0.20 H and source-current rate 3 A s⁻¹ give emf magnitude
Explanation: M|dI/dt| = 0.20 × 3.
Source current is constant and coils are fixed in a linear medium. Mutual emf is
Explanation: Linked flux is steady, so its derivative vanishes.
For long coaxial solenoids, the relevant area in M is
Explanation: Only the inner field area contributes when the inner solenoid is the source.
In the fixed reciprocal linear arrangement, M₁₂ and M₂₁ are
Explanation: The same coupling coefficient describes the two directions.
MΔI has the units of
Explanation: H × A = Wb-turn, whereas emf also involves a time rate.
Practice Problems
- M = 1.5 H and source current rises from 0 to 20 A in 0.50 s. Find linkage change and average emf magnitude.
- For a 200-turn receiver in the preceding problem, find per-turn flux change if all turns link equal flux.
- Double the outer radius of long coaxial solenoids while retaining inner area, turn densities, overlap length and air core. What happens to ideal M?
- For unequal concentric single-turn loops, derive the approximate dependence of M on small and large radii.
- A detector signal changes when one coil is moved away. Is constant M still justified?
Δλ = MΔI = 1.5 × 20 = 30 Wb-turn. Average emf magnitude = Δλ/Δt = 30/0.50 = 60 V. The supplied time affects emf but not endpoint linkage change.
Key Takeaways
• Mutual induction couples circuits through a changing linked magnetic field. • M relates receiver flux linkage to source current in a linear fixed geometry. • Mutual emf depends on current-change rate, not current alone. • Long coaxial solenoids share the inner cross-sectional field area. • Reciprocity can replace a difficult reverse field calculation. • Changing linkage MΔI and induced emf MΔI/Δt are different quantities. • Varying geometry requires differentiating the full product MI.
Finished this lesson? Mark it complete to track your progress.