Electromagnetic Induction · Lesson 2 of 9
Faraday’s Law: From Flux Change to Emf
“Use Faraday’s law with changing fields, areas, orientations and flux–time graphs.”
• Apply signed and magnitude forms of Faraday’s law. • Distinguish average emf from instantaneous emf. • Relate flux–time slope to emf and resistive current. • Explain how induced emf can exist without a closed conducting path.
The measured quantity is a rate of change
Two experiments can start and end with the same flux but produce different emf histories. Slowly moving a magnet produces a smaller emf over a longer interval; a quicker change produces a larger rate. Faraday’s law is an experimentally established relationship between induced emf and flux-linkage change. It is not derived from Ohm’s law. Electromotive force is energy transferred per unit charge around a circuit, measured in volts despite its historical name; it is not a force in newtons.
Choose a positive circuit direction first. Curl the fingers of the right hand in that direction; the thumb defines the positive normal. A positive flux slope gives a negative emf with that convention. Reversing the convention reverses both signs while preserving the physical prediction. The next lesson develops the same sign information through Lenz’s law. For N fixed, identical series turns, differentiate NΦ to obtain −N dΦ/dt. Never multiply by N again if the given quantity is already total flux linkage.
Changing field, area or orientation
For a fixed loop in a field that changes in magnitude, area and angle stay constant and emf follows the field-change rate. A loop pulled out of a field changes its effective overlap area. A rotating loop changes its normal direction. More than one variable can change at once: computing the complete flux first is safer than trying to add memorised special formulas. If changes cancel and total flux remains constant, the net flux-change emf is zero.
Problem
A square loop of side 0.10 m and total resistance 0.50 Ω has a field of 0.10 T at 45° to its normal. The field decreases uniformly to zero in 0.70 s. Find emf and current magnitudes.
- 1.Area is 0.010 m². Initial flux = 0.10 × 0.010 × cos 45° = 7.071 × 10⁻⁴ Wb; final flux is zero.
- 2.The constant magnitude of emf is |ΔΦ|/Δt = 1.01 × 10⁻³ V. Neglecting self-inductive transients, I = |emf|/R = 2.02 × 10⁻³ A.
- 3.A steady background field adds a constant flux offset and therefore contributes no emf for this fixed loop.
Slope tells the instantaneous emf
A horizontal portion of a flux–time graph means zero emf. A straight sloping portion means constant emf. A steeper slope means larger emf magnitude; an upward slope gives negative emf in the associated positive direction. At a smooth maximum or minimum of flux the slope is zero, even though flux magnitude may be large. A mathematically sharp corner gives different one-sided derivatives; real apparatus rounds the transition rather than changing current infinitely abruptly.
Problem
A 20-turn coil links Φ(t) = (0.003 Wb s⁻²)t² per turn. Find emf at 2.0 s and average emf from 0 to 2.0 s.
- 1.Differentiate first: dΦ/dt = (0.006 Wb s⁻²)t. At 2.0 s, emf = −20 × 0.012 = −0.24 V.
- 2.Over the interval, ΔΦ = 0.012 Wb, so average emf = −20 × 0.012/2.0 = −0.12 V.
- 3.Instantaneous emf at the endpoint is twice the interval average because the slope grows linearly. Endpoint flux divided by time cannot replace differentiation for an instantaneous value.
Emf and current are different
A cut loop can develop an electrical effect across its gap while it carries no sustained conduction current around the loop. In a closed circuit with negligible inductance and total resistance R, current follows emf/R. In a coil with appreciable inductance this simple instantaneous relation is incomplete; the changing current also produces self-induced emf. A larger resistance does not reduce the externally imposed flux-change emf, but it reduces the current in the resistive approximation.
For a stationary path in a changing magnetic field, the driving electric field is nonconservative: its circulation need not vanish. It cannot everywhere be represented by a single electrostatic potential. A voltage measurement in such a field can depend on the lead path, because the leads form an additional loop. In the usual small-gap arrangement with negligible extra linked flux in the leads, the measured gap voltage represents the expected induced emf. Specifying the path avoids treating an open wire as if it enclosed one unique surface by itself.
A half-turn: the final flux has the opposite sign
Problem
A 500-turn coil of radius 0.10 m is turned through 180° in 0.25 s. Initially its normal is parallel to a uniform 3.0 × 10⁻⁵ T field. Its resistance is 2.0 Ω. Find average emf magnitude.
- 1.Initial per-turn flux is BA = (3.0 × 10⁻⁵)π(0.10)² = 9.425 × 10⁻⁷ Wb. Final flux is its negative, giving |ΔΦ| = 1.885 × 10⁻⁶ Wb.
- 2.Average emf magnitude is 500 × 1.885 × 10⁻⁶/0.25 = 3.77 mV. In a purely resistive model, the magnitude of the signed average current is 1.88 mA.
- 3.This is an interval average. The instantaneous emf depends on angular speed at each instant; a smooth rotation does not generate a constant emf.
For constant resistance and negligible inductance, integrating I = −(1/R)dλ/dt gives the signed charge transfer Q = −Δλ/R. A slower and faster monotonic flux change can transfer the same charge while their current amplitudes differ. This conclusion assumes the same endpoint linkage and resistance; it is not a claim that their power or heating histories are identical.
Quick Quiz
Quiz
Flux linkage increases linearly with time. Induced emf is
Explanation: Emf equals the negative slope of linkage.
A 50-turn coil has per-turn flux change 2 mWb in 0.10 s. Average emf magnitude is
Explanation: N|ΔΦ|/Δt = 50 × 0.002/0.10.
At a smooth maximum of flux, instantaneous emf is
Explanation: The derivative is zero at a smooth extremum.
For prescribed flux change, doubling circuit resistance in a resistive model does what?
Explanation: Faraday’s law sets emf; Ohm’s law then sets current.
A 180° turn from normal parallel to B gives |ΔΦ| equal to
Explanation: Flux changes from +BA to −BA.
Practice Problems
- A 100-turn coil links per-turn flux increasing uniformly from 1 to 4 mWb in 0.20 s. Find signed emf.
- A linkage graph rises from 0 to 0.06 Wb-turn in 0.03 s, stays flat for 0.02 s and falls to zero in 0.06 s. Find emf on each part.
- For Φ = kt³ per turn and N turns, derive emf and state its time dependence.
- Can a cut coil have emf without conduction current around its loop?
- A resistive loop of 4 Ω experiences a linkage decrease of 0.020 Wb-turn. Find signed charge transfer.
Choose positive normal in the given flux direction. Δλ = 100 × 0.003 = 0.30 Wb-turn. Emf = −0.30/0.20 = −1.5 V, opposite the associated positive circuit direction.
Key Takeaways
• Faraday’s law relates emf to the negative rate of flux-linkage change. • Per-turn flux and total linkage must not be multiplied by N twice. • Average emf uses endpoint changes; instantaneous emf uses a derivative. • Flux–time graph slope determines emf, not graph height. • A closed conducting path is required for sustained loop current. • The relation I = emf/R requires a resistive approximation. • A half-turn reverses flux and gives a change of magnitude 2BA.
Finished this lesson? Mark it complete to track your progress.
Loading your progress…