Electromagnetic Induction · Lesson 9 of 9
Chapter Summary and Practice
“Connect the induction models and apply them to varied physical situations.”
• Select a flux-change or motional-force model for a stated system. • Apply direction conventions and energy checks consistently. • Combine induction, resistance, geometry and current-change rates. • Solve problems spanning the chapter and explain model limitations.
One principle connects the chapter
The induction experiments reveal a relationship between changing magnetic conditions and electric driving effects. Flux makes that relationship quantitative: it combines field, surface area and orientation. Faraday’s law uses the rate of flux-linkage change to give emf. Lenz’s law fixes its physical direction. When a path is closed, the rest of the circuit determines the resulting current. A large magnetic field with no change in linked flux can coexist with zero induced emf.
There are two complementary mechanisms in the simple systems studied here. A conductor moving through a steady field has a magnetic-force contribution along its length. A stationary loop in a changing magnetic field is driven by an induced electric field. The general moving-circuit emf includes both effects; do not add the motional formula to a complete flux-rule result a second time. The flux rule already accounts for the area change in a sliding-rod circuit.
Choose the representation before substituting
| Situation | Best first step | Main caution |
|---|---|---|
| Fixed coil, varying B | Write λ = NBA cos θ | Differentiate, rather than use flux magnitude |
| Loop crosses a field boundary | Write overlap area versus time | Use boundary-cut width for dA/dt |
| Sliding or isolated rod | Resolve v × B along rod | An open rod has voltage without a closed loop current |
| Rotating radial conductor | Use local v = ωr and integrate | Tip speed is not every segment’s speed |
| Coupled fixed coils | Write receiver linkage = M × source current | Do not confuse linkage change with emf |
| One coil’s current changes | Write self-linkage LI | Self-emf opposes change, including decrease |
| Plane coil rotates in uniform B | Write λ(t) then differentiate | Flux peaks and emf peaks occur at different times |
Formula reference with conditions
| Equation | Meaning and units | Conditions and limitations |
|---|---|---|
| Φ = BA cos θ | Flux in Wb; B in T; A in m² | Plane surface, uniform B; θ measured to normal |
| ε = −dλ/dt; λ = ΣΦₖ | Emf in V; linkage in Wb-turn | Use tracked circuit orientation; λ = NΦ only for equal per-turn flux |
| I = ε/R | Current in A; R in Ω | Closed resistive circuit; neglect self-inductive transients |
| |εrod| = Blv | Motional emf in V | Uniform B and translation; rod, B, v mutually perpendicular |
| |εrot| = ½BωR² | Rotating radial rod, ω in rad s⁻¹ | Uniform axial B, rod runs from axis to R |
| M = μn₁n₂Ainnerl | Mutual inductance in H | Long coaxial overlapping solenoids in linear medium |
| L = μN²A/l | Self-inductance in H | Long solenoid, negligible end fields, constant μ |
| εself = −L dI/dt | Self-emf in V | Fixed constant-L model; differentiate LI otherwise |
| U = ½LI²; uB = B²/(2μ₀) | Energy in J; density in J m⁻³ | Constant L; vacuum density expression |
| ε = NBAω sin ωt | Generator emf in V | Uniform B; constant speed; normal parallel B at t = 0 |
Dimensional checks connect the formulas: BA is Wb, Wb/s is V, H × A/s is V, and H × A² is J. These checks catch omitted time factors and confused flux versus emf. They cannot by themselves determine a factor one half, a cosine, a direction or whether a geometry is appropriate. A plausible unit is necessary but insufficient evidence of a correct physical model.
Direction, sign and the observer
For a plane loop begin with the normal and its associated positive circulation. Decide whether the external flux increases or decreases, then choose the induced field that opposes that change. Use the right-hand rule to translate the field into current. In a moving rod, use v × B for positive-charge tendency, then identify the high-potential end. State where the observer is before using clockwise or counterclockwise. A minus sign is meaningful only relative to a declared reference.
A field with decreasing magnitude is an especially useful check. The induced field can point along the applied field because it supports a decreasing flux. Likewise an inductor can drive current in its existing direction as current falls. Neither behaviour violates Lenz’s law; both oppose the change. In the ideal straight-wire-through-centre geometry, a coplanar magnetic field has zero normal flux, so a changing source current need not produce loop emf at all.
Derivations form a connected chain
The sliding rod starts with area A = lx. Differentiating Blx gives Blv. Multiplying induced current by Bl gives magnetic drag, and multiplying drag by speed gives the same power as I²R. The rotating rod uses the same local motional expression but speed depends on radius, so integrating r gives R²/2. These are not unrelated rules: geometry changes the integral of the same force contribution.
For inductance, first calculate the field per unit current. Next find flux per turn and multiply by receiving turns. Dividing linkage by source current gives M for two coils or L for one coil’s own field. For a long solenoid, both field production and linkage involve turn count, giving the square N² in L. To obtain stored energy, integrate the incremental work LI dI. This establishes why energy is quadratic in current rather than simply proportional to current.
Energy decides whether an answer is plausible
A sliding generator and a rotating-coil generator need mechanical work under load. In a freely decelerating device, initial kinetic energy can provide that work. In a decaying-current coil, the source can be previously stored magnetic energy. The magnetic force on a point charge does zero instantaneous work, but electromagnetic forces on a constrained conducting system can transfer mechanical input to the circuit. Identify the complete system before making an energy statement.
Problem
Two identical moving rods each generate 0.80 V. One has a closed 2.0 Ω return path; the other has an insulating gap. Compare ideal steady conduction currents and energy transfer.
- 1.The resistive circuit carries 0.80/2.0 = 0.40 A, producing 0.32 W of heat. Maintaining its motion requires corresponding mechanical power when other losses and transients are negligible.
- 2.The cut circuit has no sustained conduction loop current, though terminal charge separation and an induced emf remain. It does not supply the same steady 0.32 W load heating.
- 3.Equal emf does not imply equal current or power. The external flux process sets the driving emf; circuit conditions set how that emf transfers energy.
Problem
A circular path of radius 0.030 m lies inside a long solenoid whose uniform axial field increases at 0.20 T s⁻¹. Find induced tangential electric-field magnitude.
- 1.By circular symmetry, the induced E has constant tangential magnitude around the path. Faraday circulation gives E(2πr) = πr²|dB/dt|.
- 2.Thus E = (r/2)|dB/dt| = (0.030/2) × 0.20 = 0.0030 V m⁻¹. Its circulation direction opposes the growing flux.
- 3.The field can exist without a metal ring. A ring samples the induced field; it is not required to create that field. The expression changes outside the field-filled radius.
A reliable independent solution routine
Sketch the geometry and mark fields, normals, velocities and chosen directions. List SI data and the unknown. Decide whether linkage changes through field magnitude, overlap area, orientation, current or coupling geometry. Write the governing relationship with its assumptions before substituting. Differentiate or integrate where required; calculate magnitude and direction separately. Finally check units, limiting cases and energy supply. Zero speed, zero current-change rate, or a field parallel to a moving rod’s velocity should simplify to the appropriate zero-induction limit.
Use the chapter-wide problems to practise model selection rather than searching for a formula with matching letters. Some ask for flux linkage, some emf, some current and some energy. Their different units reveal their different physical roles. A complete answer explains both the result and why that particular model fits the system.
Quick Quiz
Quiz
A coil has zero linked flux at one instant. Its emf at that instant
Explanation: Zero flux does not imply zero derivative, as a rotating coil demonstrates.
A 0.10 H coil’s current rises at 20 A s⁻¹. Self-emf magnitude is
Explanation: L times current-change rate gives volts.
A loop leaves an into-page field. The induced field is
Explanation: It supports the decreasing into-page flux.
A radial rod in axial B and a rotating plane coil necessarily have the same waveform. This statement is
Explanation: A radial rod can have constant-polarity emf, while a suitably rotating plane coil gives alternating emf.
Which check is sufficient by itself to prove a physical answer correct?
Explanation: Geometry, assumptions, direction, calculations and physical checks must agree.
Practice Problems
- A 150-turn coil of area 0.010 m² is normal to a field falling uniformly from 0.30 T to 0.10 T in 0.050 s. R = 3 Ω. Find emf and resistive current magnitudes.
- Linkage is λ(t) = (0.040 Wb s⁻²)t². Find emf at 0.50 s and average emf from 0 to 0.50 s.
- A north pole moves left between two coaxial closed coils, with its south pole facing left and north pole facing right. Describe the induced face polarities nearest the magnet.
- An irregular fixed-perimeter plane loop expands to a circle in an into-page field. Find current direction and contrast a circular loop squeezed in an out-of-page field.
- A solenoid has 15 turns per cm. A single-turn 2.0 cm² loop lies inside, with normal along its axis. Source current rises from 2 to 4 A in 0.10 s. Find emf magnitude.
- An 8 cm by 2 cm cut loop exits a 0.30 T field at 1 cm s⁻¹. Compare both perpendicular exit directions.
- A 1.0 m radial rod rotates at 400 rad s⁻¹ in axial B = 0.50 T. Derive and calculate its emf magnitude.
- A 10 m east–west wire falls at 5 m s⁻¹ through northward horizontal B = 3.0 × 10⁻⁵ T. Find emf magnitude and polarity.
- A circuit current decreases from 5 A to zero in 0.10 s with average self-emf magnitude 200 V. Find L and initial stored energy.
- Two fixed coils have M = 1.5 H. Source current rises from 0 to 20 A in 0.50 s. Find receiver linkage change, average emf magnitude and per-turn flux change for 300 equal-linkage turns.
- An air-core solenoid has N = 500, l = 0.40 m and A = 4.0 cm². Find L and energy at 2 A.
- A 100-turn generator coil of area 0.10 m² rotates at 0.50 Hz in 0.010 T. Find peak emf and the time of its first positive peak if its normal starts parallel to B.
Per-turn flux change is AΔB = 0.010(−0.20) = −0.002 Wb. Linkage change is −0.30 Wb-turn. Average and constant emf magnitude is 0.30/0.050 = 6.0 V. With negligible inductance, I = 6.0/3 = 2.0 A. The induced field supports the original field as it decreases.
Key Takeaways
• Begin with geometry, source of flux and a stated direction convention. • Use the time derivative of linkage to calculate emf. • Distinguish flux, linkage, emf, current and energy by both meaning and units. • Direction rules oppose flux changes and require a specified viewing side. • Use local-speed integration for rotating radial conductors. • Mutual and self-induction are applications of the same Faraday principle. • Mechanical input or stored energy supplies electrical output. • Check assumptions, units, signs, limiting cases and energy balance together.
Finished this lesson? Mark it complete to track your progress.
Loading your progress…
Previous · Lesson 8
The AC Generator
Next
End of chapter