Skip to lesson content

Lesson 1 of 9

Electromagnetic Induction · Lesson 1 of 9

Experiments and Magnetic Flux

“Connect induction experiments to magnetic flux, surface orientation and flux linkage.”

Learning Objectives

• Explain the observations in three induction experiments. • Calculate signed magnetic flux through a plane surface. • Distinguish magnetic field, flux and flux linkage. • Predict whether motion or field changes can produce induction.

Prerequisite check: a changing field is measured in tesla, current in amperes and emf in volts. The area normal recalls vector geometry; the dot product selects the perpendicular field component. Later direction arguments use the right-hand grip rule for a current loop and the cross product for a moving charge. Circuit calculations use total resistance and conservation of energy. Each of these tools will be recalled where it is first needed, so remembering an entire earlier chapter is unnecessary.

A current without a direct connection to a cell

Connect an insulated wire coil to a sensitive centre-zero galvanometer. Push the north pole of a bar magnet toward the coil: the pointer deflects while the magnet moves. Hold the magnet still: after the transient, the pointer returns to zero. Withdraw the magnet: the deflection reverses. Repeating the motion faster generally produces a larger instantaneous response because the field through the coil changes faster. Reversing the pole reverses the response for otherwise similar motion. A magnetic field can be present without a sustained induced current.

The measuring circuit must be complete for this conduction current. The magnet is not supplying electric charge to the wire; mobile carriers already exist there. The galvanometer detects their organised motion. It also matters how the apparatus is held: moving the coil toward a fixed magnet gives the corresponding induction effect. Relative motion changes the magnetic conditions through the coil, but motion by itself is not the most general explanation.

Three experiments and the common variable

ArrangementObservationWhat changes?
Magnet moved toward or away from a coilOpposite deflections for approach and withdrawalMagnetic field through the coil
Current-carrying source coil moved near a detector coilDeflection during changing separationField through the detector due to source position
Two fixed coils; source current switched on or offMomentary, opposite deflections at making and breakingField through detector while source current changes

In the third experiment there need be no motion at all. After the source current settles to a steady value, the detector returns to zero although the source field remains. An iron core can increase the coupled field and signal, but a fixed core does not maintain a detector current once everything becomes steady. These observations point toward a changing magnetic quantity associated with an entire surface, rather than the field at just one point.

Two fixed coils: no mechanical motionSwitch onbrief deflectionHold current steadyzero after transientSwitch offopposite deflectionResponse follows change, rather than field strength alone.
Switching a source current: detector response— Sequence of idealised observations; pointer size is not a calibrated measurement.

An alternative detector can be a small lamp, but only if the induced voltage and current are sufficient for visible light. A weak classroom coil may produce a measurable galvanometer signal without lighting a lamp. More source-coil current, a suitable core and a faster controlled change can increase the signal; detector sensitivity and total circuit resistance still matter.

An area has an orientation

For a flat loop, choose a unit normal perpendicular to its plane. The area vector has magnitude equal to the area and points along that normal. Either of the two normals can be chosen, but retain it throughout a calculation. Magnetic flux measures the field component normal to the surface, weighted by area. Field lines are a drawing aid rather than physical threads; counting a chosen number of drawn lines does not define the measured quantity.

Flux in a uniform magnetic fieldLaTeX
B is magnetic flux density in tesla, A is area in m², and θ is the angle from the chosen normal to B. Flux is a signed scalar in weber: 1 Wb = 1 T m² = 1 V s.

When the field is perpendicular to the plane, it is parallel to a normal and the flux magnitude is BA. When the field lies in the plane, its normal component vanishes and the flux is zero. If an angle α is measured to the plane instead, use BA sin α. Turning the chosen normal around reverses the sign of flux without altering the physical surface. A negative flux means the field crosses opposite to the chosen normal; it does not mean a negative field strength.

normal ABθθ = 0°: maximum flux; θ = 90°: zero flux
The flux angle is measured from the normal— Schematic tilted surface. Both arrows start at the same point; the angle is between the arrows, not between B and the plane.

Nonuniform fields and many turns

Add the contributions of small surface elementsLaTeX
The integral adds local normal-field contributions. λ is total flux linkage. Only if all N turns link the same flux does λ = NΦ_B.

A nonuniform field cannot generally be replaced by its value at the centre multiplied by total area. Divide the surface into patches small enough that each patch has a nearly uniform field and add signed contributions; the integral is the limiting sum. Flux linkage adds the flux for every turn because each turn contributes to the series emf. The unit is often described as weber-turn, with turn a dimensionless count. Distinguish the flux through one turn from the flux linkage of a whole coil.

An angle given to the plane

Problem
A 0.020 m² loop is in a uniform 0.30 T field making 30° with its plane. Find flux magnitude.

  1. 1.The angle to the normal is 60°, so Φ = BA cos 60° = 0.30 × 0.020 × 0.5 = 3.0 × 10⁻³ Wb.
  2. 2.Using cos 30° would use the wrong angle. For a 40-turn coil with this flux through every turn, linkage is 40Φ = 0.12 Wb-turn.
Opposite contributions

Problem
Two equal 0.010 m² patches have normal components +0.20 T and −0.10 T. Find total flux.

  1. 1.Add signed fluxes: Φ = (0.20)(0.010) + (−0.10)(0.010) = 1.0 × 10⁻³ Wb.
  2. 2.Adding magnitudes would lose cancellation. The net flux can vanish even if the field is nonzero at every point.

Predict whether a rigid loop translating wholly inside a spatially uniform, steady field must show induction. Its area, orientation and field are constant, so its flux does not change. Motion alone is insufficient. By contrast, crossing a field boundary changes the part of its area threaded by field. The next lesson turns this geometric change into a quantitative emf.

Quick Quiz

Quiz

Quick check

For magnetic flux BA cos θ, θ is measured between B and what?

Explanation: The area vector is perpendicular to the surface.

Quick check

A loop is fixed in a strong, steady field. Its geometry is constant. What is the induced emf from flux change?

Explanation: Constant flux has zero time derivative.

Quick check

Two fixed coils show a detector pulse when source current changes. What does this establish?

Explanation: A changing source field can change detector flux without motion.

Quick check

A field lies in the plane of a flat loop. Its magnetic flux is

Explanation: The normal component of B is zero.

Quick check

Ten identical turns each link 0.003 Wb. Their total linkage is

Explanation: Add the flux contributions of ten turns.

Practice Problems

Practice Problems
  1. Explain why switching off a source coil reverses a nearby detector pulse.
  2. Find flux through 50 cm² in a 0.40 T field at 60° to the normal.
  3. A loop is turned from normal parallel to B to normal antiparallel to B. Is final flux zero?
  4. A 100-turn coil has 80 turns linking 2 mWb each and 20 linking 1 mWb each. Find linkage.
  5. Compare a loop moving wholly in a uniform steady field with one leaving a field region.

Switch-on increases source field and detector flux; switch-off decreases them. The changes have opposite signs. Faraday induction therefore gives opposite emf directions, so a closed detector circuit shows opposite current pulses.

Key Takeaways

Key Takeaways

• Magnetic flux weights the field component normal to a surface. • The flux angle is measured from the normal, not the plane. • Flux is a signed scalar measured in weber. • For a nonuniform field, add local signed contributions. • Flux linkage equals NΦ only when all turns link the same flux. • Induction can occur with stationary coils when source current changes. • Motion or a strong magnetic field alone does not guarantee induction.

Finished this lesson? Mark it complete to track your progress.

Loading your progress…